Estimation of 99Tcm-MAG3 clearance using a single blood sample obtained over a continuous time interval
Related Experiment Video
Updated: Oct 12, 2026

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
1Servicio de Medicina Nuclear, Hospital Clínic i Provincial, Barcelona, Spain.
Simplified methods based on a single blood sample have been proposed to estimate the clearance of 131I-hippuran (HIP) and 99Tcm-mercaptoacetyltriglycine (MAG). The blood sample is usually drawn at that time which yields a minimum error between the estimated clearance and that obtained by the standard nine-sample method. In this paper, we establish the regression equations to obtain the HIP and MAG clearances using one sample withdrawn during a fixed time interval. As HIP has long been the agent of choice, we have also established regression equations to estimate the clearance of HIP using one sample after MAG administration. Our results suggest that it is possible to obtain plasma samples 30-50 min post-injection which result in an error of the estimate only slightly higher than the minimum.
Simplified methods based on a single blood sample have been proposed to estimate the clearance of 131I-hippuran (HIP) and 99Tcm-mercaptoacetyltriglycine (MAG). The blood sample is usually drawn at that time which yields a minimum error between the estimated clearance and that obtained by the standard nine-sample method. In this paper, we establish the regression equations to obtain the HIP and MAG clearances using one sample withdrawn during a fixed time interval. As HIP has long been the agent of choice, we have also established regression equations to estimate the clearance of HIP using one sample after MAG administration. Our results suggest that it is possible to obtain plasma samples 30-50 min post-injection which result in an error of the estimate only slightly higher than the minimum.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Clearance Models: Noncompartmental Models
The noncompartmental approach capitalizes on extensive sampling data, correlating the volume of distribution to systemic exposure and the administered dosage. This method enables...