Rate-drop response programming

M D Gammage1

  • 1Department of Cardiovascular Medicine, University of Birmingham, United Kingdom. m.d.gammage@bham.ac.uk

Pacing and Clinical Electrophysiology : PACE
|March 1, 1997
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Selective site right ventricular pacing.

Heart (British Cardiac Society)·2009
Same author

Association between serum free thyroxine concentration and atrial fibrillation.

Archives of internal medicine·2007
Same author

Ablate and pace revisited: long term survival and predictors of permanent atrial fibrillation.

Heart (British Cardiac Society)·2003
Same author

The electromechanical effects of pacing at different sites within the right atrium.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology·2002
Same author

Thyroid disease and its treatment: short-term and long-term cardiovascular consequences.

Current opinion in pharmacology·2002
Same author

Thyrotoxicosis with heart block.

Journal of the Royal Society of Medicine·2001
Same journal

A Case of Permanent Pacemaker Implantation via the Epicardial Approach Using the 3830 Lead in an 11-Day-Old Neonate (With Follow-Up of the Above Case).

Pacing and clinical electrophysiology : PACE·2026
Same journal

Cryoballoon Versus Radiofrequency Ablation for Persistent Atrial Fibrillation: Meta-Analysis of Randomized Trials.

Pacing and clinical electrophysiology : PACE·2026
Same journal

Tilt Test Duration in Suspected Vasovagal Syncope: Temporal Patterns and Diagnostic Yield in Patients From Central China.

Pacing and clinical electrophysiology : PACE·2026
Same journal

Combined Leadless Pacing and Subcutaneous ICD Therapy in Long QT Syndromes.

Pacing and clinical electrophysiology : PACE·2026
Same journal

Association of Anesthesia Modality With Procedural Parameters and Clinical Outcomes in PVI for Atrial Fibrillation.

Pacing and clinical electrophysiology : PACE·2026
Same journal

Zero-Fluoroscopy Cryoballoon Ablation for Paroxysmal Atrial Fibrillation in a Patient With Dextrocardia: A Case Report.

Pacing and clinical electrophysiology : PACE·2026
See all related articles

Programming the rate-drop response algorithm for pacemakers requires precise tilt testing. Careful attention to heart rate and blood pressure changes ensures effective, individualized settings for patients experiencing syncope.

Area of Science:

  • Cardiology
  • Biomedical Engineering

Background:

  • Effective programming of pacemaker algorithms is crucial for patient outcomes.
  • The rate-drop response algorithm requires specific calibration for optimal performance.

Purpose of the Study:

  • To outline the necessary steps for effectively programming the rate-drop response algorithm.
  • To highlight the importance of diagnostic tilt testing in this process.

Main Methods:

  • Utilizing diagnostic tilt testing with identical protocols for each patient.
  • Meticulously recording the onset of symptoms, heart rate, and blood pressure changes.
  • Adjusting factory settings of the Thera DR generator for individual patient needs.

Main Results:

Related Experiment Videos

  • Factory settings for the rate-drop response algorithm are typically non-therapeutic.
  • Individualized therapeutic settings may lead to increased pacing interventions.
  • These pacing interventions are generally well-tolerated and less symptomatic than presyncope.
  • Conclusions:

    • Effective programming of the rate-drop response algorithm necessitates precise and repeatable tilt testing.
    • Individual patient data is vital for optimizing algorithm settings beyond default parameters.
    • Optimized settings can improve patient well-being by reducing symptomatic events like syncope.