Related Experiment Video
Updated: Aug 18, 2026

Correlative Light- and Electron Microscopy Using Quantum Dot Nanoparticles
Published on: August 7, 2016
Somatostatin receptor scintigraphy in patients with pituitary adenoma
A Rieger1, N G Rainov, C Elfrich
1Department of Neurosurgery, Faculty of Medicine, Martin-Luther-University Halle-Wittenberg, Fed. Rep. of Germany.
Abstract:
Presence of high-affinity somatostatin (SST) receptors in most endocrine tumor cells allow in vivo scintigraphic visualization of these neoplasms after intravenous administration of a radionuclide-labeled somatostatin analog. 111In-octreotide is at present the most often used substance for imaging of the SST receptor expression in vivo. The aim of this study is to investigate the correlation between presence of in vivo scintigraphically detectable SST receptors in pituitary tumors and clinical parameters such as patients' age, tumor size, hormonal hypersecretion, and response to octreotide therapy. Forty-two-consecutive patients were enrolled in this trial. Twenty-five of them had nonsecreting pituitary tumors, 11 were acromegalic, and 6 had macro- or microprolactinoma. Scintigraphic images of the head were obtained at 10 min and 24 hours after injection of the radionuclide. In 23 patients, no specific binding of 111In-octreotide was found. Five patients showed a weak positive, 5 had a positive, and 9 a strong positive signal in the region of interest. Uptake of octreotide was significantly correlated with tumor size and age (p < 0.01). Small-size pituitary adenomas were most likely to be scintigraphically receptor-negative, while large suprasellar tumors tended to exhibit a rather strong receptor positivity. Statistical analysis of the data could not confirm the hypothesized correlation between endocrine activity of the pituitary tumors and the scintigraphically proven SST receptor expression in vivo. A positive Octreoscan was not predictive for the result of octreotide therapy.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

