Related Experiment Video
Updated: Oct 13, 2026

Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models
Published on: March 13, 2018
Radioimmunoscintigraphy in patients with breast adenocarcinoma using technetium-99m labelled monoclonal antibody
S A McQuarrie1, G D MacLean, G R Boniface
1University of Alberta, Edmonton, Alberta, Canada.
Fifty-three women with clinical evidence of adenocarcinoma of the breast were studied with technetium-99m labelled monoclonal antibody (MAb) 170H.82 at protein doses of 1, 2 and 4 mg. An overall per lesion efficacy of 83.5% sensitivity and 97.7% positive predictive value was obtained. Efficacy appears higher in lesions restricted to the breast and local regional disease than systemic metastases. For the 2 mg dose the breast/local regional disease efficacy was 90% sensitivity and 90.2% positive predictive value. The biodistribution of this MAb was best represented by a two-compartment model with a distribution-phase half-life of 4.0+/-1.4 h, followed by an elimination-phase half-life of 39.6+/-6.6 h. In all six patients studied, the critical organ was the kidney, with a mean radiation absorbed dose of 37+/-6.9 mGy/GBq. The accuracy of this imaging technique allows the development of diagnostic strategies for the routine use of the compound in patients with breast cancer.
Fifty-three women with clinical evidence of adenocarcinoma of the breast were studied with technetium-99m labelled monoclonal antibody (MAb) 170H.82 at protein doses of 1, 2 and 4 mg. An overall per lesion efficacy of 83.5% sensitivity and 97.7% positive predictive value was obtained. Efficacy appears higher in lesions restricted to the breast and local regional disease than systemic metastases. For the 2 mg dose the breast/local regional disease efficacy was 90% sensitivity and 90.2% positive predictive value. The biodistribution of this MAb was best represented by a two-compartment model with a distribution-phase half-life of 4.0+/-1.4 h, followed by an elimination-phase half-life of 39.6+/-6.6 h. In all six patients studied, the critical organ was the kidney, with a mean radiation absorbed dose of 37+/-6.9 mGy/GBq. The accuracy of this imaging technique allows the development of diagnostic strategies for the routine use of the compound in patients with breast cancer.
More Related Videos
09:34Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography
Published on: February 17, 2022
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024