Defibrillation efficacy of commercially available biphasic impulses in humans. Importance of negative-phase peak
G Tomassoni1, K Newby, S Deshpande
1Electrophysiology Laboratory, Duke University, VA Medical Center, Durham, NC 27705, USA.
Background:
Recent studies have shown that specifically shaped biphasic waveforms can lower energy requirements for ventricular defibrillation. We prospectively compared the defibrillation efficacy of three different biphasic wave shapes incorporated in three commercially available implantable defibrillators. The results led to the development of a second protocol in which the importance of negative-phase peak voltage and duration was investigated.
Methods And Results:
Defibrillation threshold (DFT) testing using different biphasic waveforms was performed randomly on 42 patients undergoing implantation of a cardioverter-defibrillator for ventricular arrhythmias. In 23 patients (group 1), 3 waveforms were tested: a CPI waveform with 60% positive-phase (P1) tilt and 50% negative-phase (P2) tilt, a Medtronic waveform with 65% fixed tilt in both P1 and P2, and a Ventritex waveform with 60% P1 tilt and a P2 leading edge voltage equal to half of the P1 trailing edge voltage. In 19 patients (group 2), 3 biphasic waveforms with equal P1 tilt at 65% but shorter P2 duration or smaller P2 peak voltage were tested. The Endotak C 60 series lead system (CPI) was used in 11 patients in group 1 and 10 patients in group 2. A Transvene lead system (Medtronics) was used in the remaining patients. Stored energy required for defibrillation was significantly lower with the CPI waveform compared with the Ventritex waveform. In group 2, energy requirements were significantly increased for the waveform with a smaller P2 peak voltage, whereas a short P2 duration did not influence defibrillation success.
Conclusions:
Our results suggest that specifically shaped biphasic waveforms delivered from commercially available devices can affect energy requirements for defibrillation. More importantly, the amplitude of the P2 peak voltage may be a more critical determinant than the P2 duration for defibrillation success of biphasic waveforms in humans.
More Related Videos
08:55Use of a Foot-Induced Digitally Controlled Resistance Device for Functional Magnetic Resonance Imaging Evaluation in Patients with Foot Paresis
Published on: July 7, 2023
08:33Bidirectional Electrical and Optoelectronic Interfaces in Healthy and Ischemic Ex Vivo Rat Hearts
Published on: July 18, 2025
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical indicator...