Related Experiment Video
Updated: Aug 12, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Observational study of accuracy in compounding i.v. admixtures at five hospitals
E A Flynn1, R E Pearson, K N Barker
1Department of Pharmacy Care Systems, Auburn University, AL 36849-5506, USA.
Abstract:
Rates of errors in i.v. admixture compounding at five U.S. hospital pharmacies were studied. Pharmacy staff members at five hospitals representing each U.S. geographic region were observed as they compounded sterile products in order to record the medication, dose, base solution, and other details. Intravenous admixtures, antineoplastic preparations, parenteral nutrient solutions, and ready-to-use products were included. Observations took place for five days at each pharmacy. The observers' notes were checked against the labels used to prepare the doses; any deviation was considered an error. The clinical importance of each error was assessed for its potential to affect a patient adversely. The mean error rate for the five hospitals combined was 9% (145 errors for 1679 doses), excluding ready-to-use products. Mean error rates for individual pharmacies ranged from 6% to 10%. Wrong-dose errors were the most common type of error. Parenteral nutrient solutions had the highest error rates-37% for manual preparation and 22% for preparation that was partly automated. Of every 100 errors, 2 were judged to be potentially clinically important. In five U.S. hospital pharmacies, the observed error rate for compounding i.v. admixtures was 9%.
More Related Videos
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations