Related Experiment Video
Updated: Aug 10, 2026

Engineered Vascularized Muscle Flap
Published on: January 11, 2016
[Usefulness of selected parameters from the diagnostic laboratory for evaluating absorbed grafting materials]
M Szymonowicz1, S Misterka, D Paluch
1Zakład Chirurgii Eksperymentalnej i Badania Biomateriałów Katedra i Klinika Chirurgii Urazowej i Chirurgii Reki AM we Wrocławiu.
Abstract:
The results of hematologic, biochemical research and research of clotting system after intraperitoneal implantation of absorbed synthetic threads Dexon S are presented in this work. The research was made on rats of Wistar type. Blood for the research was taken 3, 7, 14, 30 and 60 days after the implantation. Morphology (Ht, Hb, MCH, WBC, the number of platelets), activity of aspartic and alanine aminotransferase and antithrombin activity, concentration of comolete protein and its fraction and concentration of glucose, urea, creatinine and also concentration of ions Na+, K+, Mg2+, Ca2+ and fibrinogen, protein C3 and C4 of complement system as well as kaolin-kephalin time and prothrombin time of plasma were marked. On the basis of the obtained results of the research it was noticed that the used methods of research constitute supplement of biological estimation of absorbed grafting materials.