Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Standards for radioiodines

B M Coursey1

  • 1Ionizing Radiation Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.

Thyroid : Official Journal of the American Thyroid Association
|April 1, 1997
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Preparation and Calibration of Carrier-Free <sup>209</sup>Po Solution Standards.

Journal of research of the National Institute of Standards and Technology·2017
Same author

Standards of radium-226: from Marie Curie to the International Committee for Radionuclide Metrology.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2002
Same author

Well-ionization chamber response relative to NIST air-kerma strength standard for prostate brachytherapy seeds.

Medical physics·2000
Same author

Recommendations of the American Association of Physicists in Medicine on 103Pd interstitial source calibration and dosimetry: implications for dose specification and prescription.

Medical physics·2000
Same author

Needs for radioactivity standards and measurements in the life sciences.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2000
Same author

On the use of apparent activity (Aapp) for treatment planning of 125I and 103Pd interstitial brachytherapy sources: recommendations of the American Association of Physicists in Medicine radiation therapy committee subcommittee on low-energy brachytherapy source dosimetry.

Medical physics·2000
Same journal

Stimulating Thyrotropin Receptor Antibodies Enhance the Expression of Both Thyrotropin Receptors and Insulin-Like Growth Factor 1 Receptors in Fibroblasts.

Thyroid : official journal of the American Thyroid Association·2026
Same journal

Mild Thyroid Eye Disease-The Most Common yet the Least Studied Presentation of Thyroid Eye Disease.

Thyroid : official journal of the American Thyroid Association·2026
Same journal

In Memoriam: Lawrence Crane Wood (1935-2026).

Thyroid : official journal of the American Thyroid Association·2026
Same journal

Trends in Management and Outcomes of Pediatric Hyperthyroidism Over Two Decades.

Thyroid : official journal of the American Thyroid Association·2026
Same journal

Targeted Therapy-Induced Erythrocytosis in Thyroid Cancers: An Underrecognized Safety Signal from a Retrospective Study.

Thyroid : official journal of the American Thyroid Association·2026
Same journal

<i>Retraction Notice:</i> High Iodine Concentration Attenuates <i>RET/PTC3</i> Oncogene Activation in Thyroid Follicular Cells.

Thyroid : official journal of the American Thyroid Association·2026
See all related articles

The National Institute of Standards and Technology provides essential radioactivity Standard Reference Materials (SRMs) for radioiodines. These materials ensure quality control in radiopharmaceutical manufacturing and accurate medical diagnostics.

Area of Science:

  • Metrology
  • Nuclear Science
  • Radiopharmaceutical Quality Control

Background:

  • The National Institute of Standards and Technology (NIST) is the primary standards laboratory for civilian technology in the United States.
  • NIST develops and maintains physical measurement standards crucial for medical diagnostics and therapy.
  • For five decades, NIST has been instrumental in providing radioactivity Standard Reference Materials (SRMs) for radioiodines.

Purpose of the Study:

  • To detail the methods used by NIST for standardizing radioiodine isotopes.
  • To highlight the availability and importance of NIST-developed radioactivity SRMs.
  • To underscore NIST's role in supporting the radiopharmaceutical industry's quality assurance.

Main Methods:

  • Standardization of Iodine-131 (131I) using 4 pi beta-gamma coincidence counting.

Related Experiment Videos

  • Standardization of Iodine-129 (129I) utilizing 4 pi beta-gamma anti-coincidence counting.
  • Employing 4 pi(e,x)-gamma coincidence counting for Iodine-123 (123I) and x-gamma sum peak coincidence counting for Iodine-125 (125I).
  • Calibration of dose calibrators and scintillation counters using NIST-standardized sources.
  • Main Results:

    • NIST has established robust methods for standardizing key radioiodine isotopes.
    • Radioiodine SRMs, including 131I and 125I, are available annually.
    • The long-lived 129I SRM has been reissued, ensuring continued availability.

    Conclusions:

    • NIST's radioactivity SRMs and standardization methods are vital for the radiopharmaceutical industry.
    • These resources ensure the accuracy and reliability of medical radioiodine products.
    • NIST's ongoing contributions support advancements in nuclear medicine and diagnostics.