Radiofrequency catheter ablation of accessory atrioventricular pathways: primary failure and recurrence of conduction
1Department of Cardiological Sciences, St George's Hospital Medical School, London.
Objective:
To identify possible factors associated with primary failure of radiofrequency ablation of accessory pathways or recurrence of accessory pathway conduction.
Patients And Methods:
Radiofrequency ablation of accessory pathways failed in 25 of 243 patients, and recurrence of accessory pathway conduction occurred in an additional 13 patients. Factors possibly related to primary failure and recurrence were analysed.
Results:
Primary failure and recurrence were less frequent in patients with left sided pathways (7% v 19%; 4% v 24%; P = 0.04). The factors that might relate to primary failure included an unstable catheter position (seven patients), a possible epicardial pathway (six patients), or misdiagnosis of accessory pathway location (two patients). The major factors for recurrence included the stability of the local atrial electrogram < or = 0.5 together with the stability of the local ventricular electrogram < or = 0.8, and prolonged time to pathway conduction block > or = 12 seconds). Thirty one patients underwent repeat ablation which was successful in 28.
Conclusions:
Primary failure and recurrence were more frequent in patients with right sided pathways. An unstable catheter position and a possible epicardial pathway location are the main contributing factors for primary failure, while unstable local electrograms and prolonged time to block are independent predictors for recurrence.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Dysrhythmias VI: Management of Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias