Related Experiment Video
Updated: Aug 19, 2026

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
[Anatomic distribution, conduction properties and recurrences after ablation of multiple in comparison with single
M Schlüter1, C A Schlüter, R Cappato
1Allgemeines Krankenhaus St Georg 2. Medizinische Abteilung, Hamburg.
Abstract:
In 1076 consecutive patients referred for radiofrequency current catheter ablation, the anatomical distribution and conduction properties of accessory pathways (APs) as well as the mode of recurrence after ablation were retrospectively analyzed and compared in patients with multiple and single APs. Except for 17 patients with Ebstein's anomaly, the prevalence of patients of multiple APs in this cohort was 5.4%. Patients with multiple APs. as opposed to patients with a single AP, had significantly more often APs located on the right free wall (23% versus 10%) and--since the prevalence of septal APs was identical in both groups--less frequently APs located on the left free wall (44% versus 56%). Also, concealed APs were significantly more often encountered in patients with multiple APs (45% versus 24%). Recurrence of conduction across an AP which had presumably been ablated was observed in both groups with statistically equal incidence of < 5%. In 11 patients with multiple APs, the additional AP was only found at the repeat session. These "new" APs were mostly concealed (9 out of 11) and necessitated an intervention predominantly late after the initial ablation session. Intermittent concealed conduction appears to be a likely explanation for this phenomenon. Patients with multiple APs exhibit a higher incidence of right free-wall and concealed APs, yet they stand the same, approximately 95%, chance of cure as do patients with a single AP. Nearly 25% percent of repeat sessions in patients initially thought to have a single AP are caused by the late manifestation of an additional AP.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Propagation of Action Potentials
Neurons (nerve cells) have a resting membrane potential, with a slightly negative charge inside compared to outside. This is maintained by ion channels, such as sodium (Na+) and potassium (K+) channels, which control the flow of ions. When a stimulus, like a touch or a signal from another neuron, triggers the neuron, sodium channels open, allowing sodium ions to...
Neural Circuits
Neuronal pools are collections of nerve cells with similar functions and interact through chemical and electrical signals. These pools include both interneurons (the central neural circuit nodes that...
Electrophysiology of Normal Cardiac Rhythm
Superposition Theorem for AC Circuits
The principle of superposition stipulates that the output of a linear circuit with several concurrent inputs is equivalent to the...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...