Water bath and contact methods in ultrasonic evaluation of bone
Related Experiment Video
Updated: Nov 1, 2026

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
K D Häusler1, P A Rich, E B Barry
1Department of Anatomy and Physiology, Royal Melbourne Institute of Technology, Plenty Rd., Bundoora Melbourne, Australia 3083.
Abstract:
Ultrasonic devices for the measurement of speed of sound (SOS) and broadband ultrasonic attenuation (BUA) generally use either a contact or water bath method. The aim of this study was to compare these two methods while determining the influence of soft tissue, pathlength (heel width and bone width), and a fixed heel dimension on SOS (m/second) and BUA (dB/MHz). Ultrasonic measurements were made using a CUBA Research system utilizing a pair of 1 MHz unfocused transducers with mean precision CV = 0.7% and 6.0% for all SOS and BUA measurements, respectively. SOS and BUA were determined in 24 human cadaveric heels under three conditions: contact method (heel intact), water bath method (heel intact), water bath method (no soft tissue). Although there were significant differences between measurements using contact and water bath techniques (heel intact), their correlations were high (r = 0.858 for SOS and r = 0. 937 for BUA; P < 0.001). After removal of soft tissue, SOS significantly increased (78 m/second; P < 0.001) whereas there was no change in BUA (P > 0.05). Heel width correlated with SOS measurements (-0.224 < r < -0.347; P < 0.001) and bone width correlated with BUA measurements (0.198 < r < 0.276; P < 0.001). The practice of using a fixed heel dimension (Lunar Achilles) was investigated by comparing SOS calculated with measured heel thickness and a value of 4 cm (Lunar Achilles). SOS increased by 42 m/second (2.7%) using the fixed heel dimension compared with measured heel widths. This study demonstrates the similarity between contact and water bath-based methods, while showing that the presence of soft tissue reduces SOS but has no effect on BUA. The use of a fixed heel dimension for calculation of SOS overestimates values obtained when using measured heel dimensions, though the values correlate highly (r = 0.98, P < 0.001). In addition, an increase in heel width tends to cause an underestimation of SOS whereas an increase in bone width tends to overestimate BUA, although the effects are relatively small.
More Related Videos
04:36Vacuum-Sealed Hot Water Bath Immersion for the Preparation of Anatomical and Surgical Cadaveric Bone Models
Published on: December 2, 2022
09:05Generation and Quantitative Analysis of Pulsed Low Frequency Ultrasound to Determine the Sonic Sensitivity of Untreated and Treated Neoplastic Cells
Published on: July 22, 2015
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...