Related Experiment Video
Updated: Jul 21, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Effect of a centralizing device on cement mantle deficiencies and initial prosthetic alignment in total hip
1Department of Orthopaedic Surgery, University of Pittsburgh, Pennsylvania, USA.
Abstract:
Sixty consecutive patients undergoing a primary hybrid total hip arthroplasty were randomized to receive a femoral component either with or without a distal centralizing device. The group with a centralizer had significantly fewer patients with cement mantle deficiencies (excessively thin areas of cement) than the group without a centralizer (P < .001). Furthermore, the centralizer group was, on average, in a neutral alignment, whereas the group without a centralizer was in a varus alignment (P < .001). It was concluded that the distal centralizing device significantly decreases the incidence of cement mantle deficiences and reproducibly aids in achieving a more neutral prosthetic alignment.