Diffusion-weighted multiple shot echo planar imaging of humans without navigation

M D Robson1, A W Anderson, J C Gore

  • 1Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, Connecticut 06520-8042, USA.

Magnetic Resonance in Medicine
|July 1, 1997
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The nature and interpretation of BOLD signals in white matter - A review.

Magnetic resonance imaging·2025
Same author

Whole genome duplication drives transcriptome reprogramming in response to drought in alfalfa.

Plant cell reports·2025
Same author

Polyploidization-driven transcriptomic dynamics in Medicago sativa neotetraploids: mRNA, smRNA and allele-specific gene expression.

BMC plant biology·2025
Same author

Exploratory Multisite MR Spectroscopic Imaging Shows White Matter Neuroaxonal Loss Associated with Complications of Type 1 Diabetes in Children.

AJNR. American journal of neuroradiology·2023
Same author

LEARNING 3D WHITE MATTER MICROSTRUCTURE FROM 2D HISTOLOGY.

Proceedings. IEEE International Symposium on Biomedical Imaging·2020
Same author

Tissue sodium content in patients with systemic lupus erythematosus: association with disease activity and markers of inflammation.

Lupus·2020

This article presents a novel technique to improve image quality in diffusion-weighted scans. By estimating and correcting for subject movement without needing extra navigation data, the method reduces common distortions. This approach works for various scanning patterns and has been successfully tested in human subjects.

Area of Science:

  • Medical imaging physics within diffusion-weighted imaging research
  • Biomedical engineering and signal processing

Background:

Current diagnostic imaging faces significant limitations due to motion-induced distortions during data acquisition. Conventional reconstruction techniques often struggle to produce clear images when subjects move slightly during scanning. This gap motivated the development of more robust processing strategies. Prior research has shown that bulk movement frequently compromises the integrity of diffusion-weighted datasets. That uncertainty drove investigators to seek ways to compensate for these errors without relying on external tracking. No prior work had resolved how to effectively estimate displacement directly from the acquired signal. Standard approaches often require additional navigation sequences that increase total scan time. This study addresses these challenges by proposing a novel framework for motion correction.

Purpose Of The Study:

The aim of this research is to develop a robust method for mitigating artifacts in diffusion-weighted imaging. These distortions frequently arise during multi-shot acquisitions due to subject movement and signal inconsistencies. The authors seek to eliminate the reliance on traditional navigation sequences which often complicate the scanning process. This study addresses the challenge of estimating bulk motion directly from the acquired data itself. The researchers intend to provide a more efficient reconstruction pipeline for clinical applications. By focusing on the background signal, they aim to create a reliable metric for assessing correction accuracy. This work is motivated by the need for higher quality images in the presence of unavoidable patient motion. The authors propose that their approach will enhance the utility of multi-shot protocols in diagnostic settings.

Keywords:
magnetic resonance imagingmotion correctionsignal processingartifact reduction

Frequently Asked Questions

The authors propose a technique that estimates subject displacement directly from the acquired signal. By minimizing ghosting effects through background signal analysis, the method corrects for bulk motion without requiring extra navigation data during the scanning process.

The researchers utilize multi-shot echo planar acquisitions to capture data. They evaluate the performance of this approach using both mosaic and interleaved sampling schemes, which are common configurations in modern magnetic resonance imaging systems.

The authors suggest that background signal intensity is necessary for estimating the accuracy of motion compensation. This metric allows the system to determine if the displacement corrections have successfully minimized ghosting artifacts in the final reconstructed image.

The researchers employ computer simulations, phantom models, and human subjects to validate their approach. These diverse data types allow for a comprehensive assessment of the correction algorithm across controlled and realistic environments.

Related Experiment Videos

Main Methods:

The investigators developed a novel algorithm to estimate and rectify displacement errors directly from raw signal inputs. Their review approach involved testing the framework through rigorous computer simulations to establish baseline performance. They subsequently validated the technique using physical phantom models to mimic complex human tissue structures. The team applied the correction to human datasets acquired with two-shot and four-shot configurations. They implemented both mosaic and interleaved sampling strategies to ensure broad applicability across different hardware settings. The researchers focused on minimizing ghosting by iteratively adjusting data based on background signal levels. This process allowed for the precise calculation of movement parameters without external tracking hardware. The study design prioritized the integration of motion compensation into the standard reconstruction pipeline.

Main Results:

The authors report that their technique successfully reduces ghosting artifacts in multi-shot acquisitions. Their findings demonstrate that displacement can be accurately estimated without the need for additional navigation sequences. The study confirms that the correction algorithm performs effectively across both two-shot and four-shot scanning protocols. Results from phantom testing show significant improvements in image clarity compared to conventional reconstruction methods. Human trials indicate that the approach maintains high fidelity even when subjects exhibit minor bulk movement. The data suggest that background signal analysis provides a consistent metric for verifying the success of the compensation. The researchers observed that both mosaic and interleaved sampling schemes benefited from the proposed correction. These outcomes indicate that the method provides a reliable solution for mitigating motion-related distortions in clinical scans.

Conclusions:

The researchers propose that their novel correction framework effectively minimizes ghosting artifacts in multi-shot imaging. This synthesis suggests that direct estimation of displacement from acquired signals provides a viable alternative to traditional navigation. The authors demonstrate that their approach functions across both mosaic and interleaved sampling patterns. Their findings imply that motion compensation can be achieved without requiring supplementary data collection sequences. The study confirms that performance remains consistent across two-shot and four-shot acquisition protocols. The evidence indicates that background signal analysis serves as a reliable metric for assessing correction accuracy. These results suggest that the technique improves overall image quality in human subjects. The authors conclude that this method offers a practical path toward reducing motion-related errors in clinical settings.

The performance is measured by the reduction of ghosting artifacts in the resulting images. The researchers specifically compare the quality of reconstructions between uncorrected data and data processed with their new motion compensation algorithm.

The authors propose that their method provides a robust way to handle subject movement in clinical imaging. They suggest this approach could simplify workflows by removing the need for additional navigation sequences during diffusion-weighted scans.