Direct intraoperative measurement of human brain temperature
Related Experiment Video
Updated: Nov 1, 2026

Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
J G Stone1, R R Goodman, K Z Baker
1Department of Anesthesiology, College of Physicians and Surgeons, Columbia University, New York, New York, USA.
Objective:
Because hypothermia enhances human tolerance for cerebral ischemia, profound hypothermia is induced in many centers so that the circulation can be arrested while clips are applied to high-risk giant cerebral aneurysms. Brain temperature is measured directly with an intracerebral probe that avoids the uncertainty of surrogate monitoring. However, when there is a large thermal gradient between brain temperature and that of the operating room, even direct measurements can sometimes be misleading. This study was undertaken to determine how deeply a thermal sensor must be embedded in the cerebral parenchyma to ensure that the ambient environment does not distort the measurement of brain temperature.
Methods:
Each of 39 normothermic patients had a thermocouple sensor inserted into a temporal lobe seizure focus just before its resection. Brain temperature was measured as the sensor was withdrawn in stages.
Results:
At both 3 and 2 cm beneath the cortical surface, the temperature of the brain was essentially the same. However, when the sensor was withdrawn to 1 cm, recorded temperature decreased from 35.7 +/- 0.9 to 34.3 +/- 1.4 degrees C (P < 0.001) and irrigation in the vicinity caused major thermal change. At shallower depths, even lower brain temperatures were recorded. No morbidity was attributable to the temperature measurements.
Conclusion:
Direct intraoperative measurement of human brain temperature is feasible and safe, but accuracy requires that the temperature sensor be inserted at least 2 cm into the cerebral cortex.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...