Related Experiment Video
Updated: Aug 10, 2026

In Vivo Imaging and Tracking of Technetium-99m Labeled Bone Marrow Mesenchymal Stem Cells in Equine Tendinopathy
Published on: December 9, 2015
Technetium-99m human immunoglobulin (HIG): a new substance for scintigraphic detection of bone and joint infections
H G Machens1, N Pallua, M Becker
1Department of Plastic, Hand and Reconstructive Surgery, Hannover Medical School, Germany.
Abstract:
Technetium (99m-Tc)-labelled, polyclonal human immunoglobulin (HIG) has been described as a new agent to detect local infection and inflammation. In this study, we tested 99m-Tc HIG in 55 patients with suspected chronic (n = 42) and acute (n = 13) skeletal infection. Diagnosis was proven operatively (n = 44) and clinically (n = 11), including microbiological culture tests (n = 46). A gamma camera scan was performed 4 and 24 hours after I.v. injection of 500 MBq 99m-Tc-HIG. 99m-Tc-HIG scanning achieved a sensitivity of 91% and a specificity of 93%. We found one false negative and five false positive scintigraphic results in 55 patients. No clinical or biochemical side effects were encountered after 99m-Tc-HIG injection. We recommend this technique especially for localisation of low-grade, chronic osteomyelitis. The mechanisms and kinetics of 99m-Tc-HIG, however, are worth investigating more extensively.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET