Related Experiment Video
Updated: Aug 16, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
The interdependence of staff and patient doses in interventional radiology
1Department of Medical Physics and Medical Engineering, Western General Hospital, Edinburgh, UK.
Abstract:
Staff doses arising from the use of X-rays are principally due to scattered radiation. This is related to the dose received by the patient expressed as the dose-area product (DAP). Doses to patients in interventional radiology are generally higher than for other fluoroscopically guided procedures. Doses to interventional radiologists are, therefore, amongst the highest associated with the use of diagnostic X-rays. The results of staff dose monitoring normalized to DAP should provide an indicator of those procedures which are associated with particularly high radiation exposures to staff, and should help to identify those radiologists whose practice may result in unnecessarily high doses to themselves. A study has been made of patient doses in two X-ray rooms used for interventional procedures associated with vascular and liver diseases. Doses to radiologists in these rooms were normalized to DAP. It was found that the average doses to the body, neck and hands were 0.05, 0.89 and 2.45 microSv/(Gy cm2), respectively for those radiologists with no significant involvement in hepatobiliary procedures. Higher doses were found for one radiologist whose workload included biliary drainage. The whole body dose was 0.17 microSv/(Gy cm2) or 5.8 mSv per year. It was shown that the doses to the neck and hands for the biliary drainage work was 6.59 and 29.0 microSv/(Gy cm2), respectively. This study has demonstrated the value of DAP as a measure of radiologist workload in respect of its significance in terms of staff dose.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Dosage Regimen: Individualization
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions