Related Experiment Video
Updated: Jul 26, 2026

07:37
Mouse Models for Graft Arteriosclerosis
Published on: May 14, 2013
Repair of aortoesophageal fistula after aortic grafting
P H Wickstrom1, J M Streitz, R V Erickson
1Department of Thoracic and Cardiovascular Surgery, Duluth Clinic, Minnesota 55805, USA.
The Annals of Thoracic Surgery
|July 1, 1997
Abstract:
This report describes repair of an aortoesophageal fistula caused by a previously placed thoracic aortic graft. The diagnosis was made by esophagoscopy. The repair consisted of femoral-to-femoral cardiopulmonary bypass, excision of the old graft, placement of a new graft, esophagectomy, cervical esophagostomy, gastrostomy, and later reconstruction by cervical esophagogastrostomy.