Related Experiment Video
Updated: Aug 10, 2026

Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Effect of severity of pulmonary disease on nitrous oxide washin and washout characteristics
P Vichitvejpaisal1, G P Joshi, J Liu
1Department of Anesthesiology and Pain Management, University of Texas Southwestern Medical Center at Dallas, USA.
Abstract:
The influence of chronic obstructive pulmonary disease (COPD) on the nitrous oxide (N2O) washin and washout characteristics was evaluated in 90 (ASA II-III) males undergoing elective peripheral surgery under general anaesthesia with controlled ventilation. Patients were classified by preoperative bedside pulmonary function testing into three groups. Group I (n = 30), patients without COPD (FEV1/FVC > 80% predicted values; control group); Group II (n = 30), patients with mild COPD (FEV1/FVC = 65-79% of predicted values); and Group III (n = 30), patients with moderate COPD (FEV1/FVC = 50-64% of predicted values). The anaesthetic technique was standardized for all patients. The Datex Capnomac Ultima monitor was used to measure the inspired and expired concentrations of nitrous oxide (N2O), carbon dioxide (CO2), and isoflurane. The duration of both N2O washin (time from start of N2O administration to equilibrium of inspired and expired N2O concentrations) and 5 per cent washout (time from discontinuation of N2O to an expired N2O concentration of 5 per cent of the equilibrium value) were recorded. The duration of N2O washin and washout were significantly prolonged in Groups II and III (P < 0.001) as compared to the control group (Group I). The end-tidal CO2 concentration decreased significantly during N2O washout without causing oxygen desaturation (SpO2 < 90%). We conclude that the duration of N2O washin and washout were significantly prolonged in anaesthetized patients with COPD which may delay the induction and recovery from N2O anaesthesia.
More Related Videos
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Related Concept Videos
2° Amines to N-Nitrosamines: Reaction with NaNO2
Inhalational Anesthetics: Overview
Factors Affecting Dissolution: Particle Size and Effective Surface Area