Patient dose due to colon examination: dose assessment and results from a survey in The Netherlands
J Geleijns1, J J Broerse, M P Shaw
1Department of Clinical Oncology, University Hospital Leiden, The Netherlands.
Purpose:
To determine the effective dose to the patient during radiographic colon examination.
Materials And Methods:
The integral dose-area product was measured during colon examination in 1,733 patients aged 18-94 years. The effective dose was estimated from the dose-area product through computer simulations of radiation transport in anthropomorphic phantoms. The relation between patient dose and imaging or radiographic technique was considered. Patient dose from a biphasic colon examination was compared to that from a double-contrast examination.
Results:
The factors for converting dose-area product to effective dose were 0.29 mSv x Gy(-1) x cm(-2) and 0.27 mSv x Gy(-1) x cm(-2) for the biphasic and the double-contrast studies, respectively. The average dose-area product for the biphasic colon examination was 21 Gy x cm2, of which 13 Gy x cm2 was attributed to the double-contrast views. The average dose-area product was 29 Gy x cm2 (range, 18-53 Gy x cm2); the average effective dose was 4.7 mSv (range, 2.7-8.4 mSv).
Conclusion:
Careful selection of the radiologic technique resulted in a surprisingly low dose during the biphasic colon examination. It is recommended that additional filtration of at least 0.1-mm copper be applied and that a screen-film combination with a speed class of at least 400 be used. Dose reduction when using digital techniques is often not realized in clinical practice.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures II: Colonoscopy
Dose Size and Dosing Frequency: Determination Methods
Dosage Interval and Administration Route: Determination Methods
Drug Dosing: Infants and Children