Left ventricular assist device support of medically unresponsive pulmonary hypertension and aortic insufficiency
R M Adamson1, W P Dembitsky, B E Jaski
1Sharp Memorial Hospital, San Diego, California, USA.
Abstract:
Most centers consider medically unresponsive pulmonary hypertension an absolute contraindication to orthotopic cardiac transplantation because the alternative surgical therapy, heterotopic graft placement, is associated with decreased survival, although most patients normalize their pulmonary hemodynamics postoperatively. Orthotopic transplantation in patients with elevated, but responsive pulmonary pressures, also is associated with an increased operative mortality rate and decreased long-term survival. The authors present the case of a patient with medically unresponsive pulmonary hypertension who was mechanically supported in an effort to improve his orthotopic transplant candidacy and decrease his risk. After informed consent, a HeartMate left ventricular assist device (LVAD) was inserted and the pulmonary hemodynamic response was monitored. Immediately before LVAD insertion, the pulmonary artery pressure (PA) was 74/28 mmHg with a transpulmonary gradient (TPG) of 28 mmHg, and a pulmonary vascular resistance (PVR) of 6.6 Wood units, despite prolonged dobutamine, milrinone, and prostaglandin E1 infusions. After 10 weeks of LVAD support, pressure and resistance improved; pulmonary artery pressure was 28/15 mmHg, transpulmonary gradient was 15 mmHg, and pulmonary vascular resistance was 2.8 Wood units. This patient subsequently underwent an uneventful orthotopic heart transplant. At 1 year after transplantation, pulmonary artery hemodynamics were normal (PA 34/14 mmHg, TPG at 8 mmHg, and PVR at 1.5 Wood units). The authors recommend the consideration of LVAD placement in patients with medically unresponsive pulmonary artery hypertension to assess PA responsiveness and improve the patient's orthotopic cardiac transplant candidacy and decrease the operative risk. However, several weeks may be needed for normalization of pressure and resistance.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
Related Concept Videos
Mitral Stenosis III: Medical Management
Aortic Regurgitation III: Medical Management
Heart Failure V: Medical Management
Heart Failure VI: Adjunct Therapies
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy V: Interprofessional Care