Monitoring considerations for port-access cardiac surgery
L C Siegel1, F G St Goar, J H Stevens
1Department of Anesthesia, Stanford University School of Medicine, Calif, USA. lsiegel@leland.stanford.edu
Background:
A method for monitoring patients was evaluated in a clinical trial of minimally invasive port-access cardiac surgery with closed chest endovascular cardiopulmonary bypass.
Methods And Results:
Cardiopulmonary bypass was conducted in 25 patients through femoral cannulas. An endovascular pulmonary artery vent was placed in the main pulmonary artery through a jugular vein. For mitral valve surgery, a catheter was placed in the coronary sinus for delivery of cardioplegia. A balloon catheter ("endoaortic clamp," EAC) used for occlusion of the ascending aorta, delivery of cardioplegia, aortic root venting, and pressure measurement was inserted through a femoral artery and initially positioned by use of fluoroscopy and transesophageal echocardiography (TEE). Potential migration of the EAC was monitored by (1) TEE of the ascending aorta, (2) pulsed-wave Doppler of the right carotid artery, (3) balloon pressure, (4) comparison of aortic root pressure and right radial artery pressure, and (5) fluoroscopy. TEE, fluoroscopy, and pressure measurement were effective in monitoring catheter insertion and position. With inadequate balloon inflation, migration of the EAC toward the aortic valve could be detected with TEE. During administration of cardioplegia, TEE showed movement of the balloon away from the aortic valve, and migration into the aortic arch was detectable with loss of carotid Doppler flow. Stability of EAC position was demonstrated with appropriate balloon volume. Cardioplegic solution was visualized in the aortic root, and aortic root pressure changed appropriately during administration of cardioplegia. Venous cannula position was optimized with TEE and endopulmonary vent flow measurement.
Conclusions:
An effective method has been developed for monitoring patients and the catheter system during port-access cardiac surgery.
More Related Videos
05:25Surgical Porcine Model of Chronic Myocardial Ischemia Treated by Exosome-laden Collagen Patch and Off-pump Coronary Artery Bypass Graft
Published on: September 15, 2023
05:51Computed Tomography (CT) Guided Implantation of a Totally Implantable Venous Access Port (TIVAP) through Subclavian Vein
Published on: January 13, 2026
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Cardiac Catheterization IV: Nursing Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Peripheral Artery Disease V: Postoperative Nursing Management
Aneurysm IV: Nursing Management