Related Experiment Videos
[Determination of tetracycline in bones, mechanically separated bones and meat using HPLC and microbiological plating
1University of Veterinary Medicine, Kosice, Slovak Republic. hygiena@vsnov.uvm.sk
Veterinarni Medicina
|May 1, 1997
Abstract:
HPLC method with solid phase extraction, and microbiological agar diffusion tests for determination of oxytetracycline (OTC), tetracycline (TC) and chlortetracycline (CTC) in bones, mechanically separated beef and bones were developed. Both mechanically separated bones and bovine flat bones showed the highest yield of tetracyclines by HPLC method. Among tetracyclines, the highest yield was determined in chlortetracycline. The strains of Bacillus subtilis (PH 6.0) and B. stearothermophilus showed the highest sensitivity to the presence of tetracyclines.