Sutural expansion using rigidly integrated endosseous implants: an experimental study in rabbits
J A Parr1, L P Garetto, M E Wohlford
1Indiana University School of Dentistry, Indianapolis 46202, USA.
The Angle Orthodontist
|January 1, 1997
Summary
Rigidly integrated endosseous implants can expand unfused sutures with low loads (1-3 N). This study in rabbits showed increased expansion with higher loads but no difference in bone formation rates.
Area of Science:
- Orthodontic and orthopedic anchorage
- Biomaterials and tissue engineering
- Craniofacial development and regeneration
Background:
- Rigidly integrated implants are crucial for orthodontic and orthopedic anchorage.
- They offer solutions for tooth movement control, edentulous arch abutments, and vertical dimension modification.
Purpose of the Study:
- To evaluate the efficacy of endosseous implants for midfacial expansion.
- To assess the effects of controlled loading on unfused sutures.
Main Methods:
- Two flanged titanium implants were placed across the midnasal suture in New Zealand White rabbits.
- Animals were subjected to unloaded control, 1 N, or 3 N loading for 12 weeks.
- Stereologic analysis of microradiography and fluorochrome histology assessed bone and suture changes.
Main Results:
- Implants remained stable; loaded groups showed significant inter-implant distance increase compared to controls.
- The 3 N group exhibited greater expansion than the 1 N group.
- Bone volume decreased, suture volume increased, and bone formation rates at sutural surfaces were elevated in loaded groups.
Conclusions:
- Low loads (1-3 N) on rigidly integrated implants across unfused sutures can achieve satisfactory expansion.
- Higher loads (3 N) promote slightly more expansion without negatively impacting bone formation rates.