Related Experiment Video
Updated: Aug 16, 2026

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Arterial-pulse oximetry loops: a new method of monitoring vascular tone
K H Shelley1, W B Murray, D Chang
1Department of Anesthesiology, Pennsylvania State University, College of Medicine, Hershey 17033, USA.
Objective:
We report the off-line calculation of the vascular compliance of the finger and suggest the continuous on-line use of this methodology as an aid to monitoring the peripheral vascular resistance. This method consists of the simultaneous analysis of the waveform signals from the pulse oximeter monitors and the arterial pressure as indicators of "volume" and pressure respectively to continuously calculate the vascular "compliance" (volume change per unit pressure change). This should be seen as a "relative compliance" as the pulse plethysmograph signal is not calibrated. This new methodology allows for continuous monitoring of peripheral vascular compliance as a beat-to-beat indicator of peripheral vascular resistance. The vaso-constrictors, phenylephrine and ephedrine, were shown to decrease the compliance as predicted.
Methods:
The arterial pressure and pulse oximeter waveforms were obtained during routine anesthetic care. The waveforms were collected with a computer data-acquisition system and then analyzed "off-line" as an indirect indicator of total vascular tone. Demographic and clinical information including drug administration were recorded.
Results:
A case report is presented using this new form of analysis. Vascular compliance changes induced by phenylephrine and ephedrine were studied. A dose response curve of peripheral vascular compliance to phenylephrine was generated from these data.
Conclusions:
By plotting the pulse oximeter waveforms versus the arterial waveforms, multiple volume versus pressure (relative compliance) loops were obtained. Analysis of these loops may assist in the monitoring of vascular compliance.
More Related Videos
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical indicator...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...