Related Experiment Video
Updated: Aug 9, 2026

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
[Description and preliminary clinical assessment of a digital chest radiographic system with selenium detector
G L Sergiacomi1, M G Ciolfi, A Certo
1Istituto di Radiologia dell'Università Tor Vergata, Ospedale S. Eugenio, Roma.
Abstract:
The authors describe an innovative digital chest imaging system (Thoravision, Philips Medical System) based on a selenium detector directly converting X-rays in electric charges detectable by electrometers, amplified and digitalized to be sent to the imaging processor. The study was performed on a series of up to 7000 digital chest X-ray examinations and a sample of 173 cases was selected on the basis of particular diseases and pathologic patterns. In the latter case, digital and conventional radiographic techniques were compared. According to this analysis, the digital system was slightly superior in detecting anatomical details, small pleural effusions (3 cases) and slight low contrast interstitial pathologic changes, mainly in apical (12 cases) and retrocardiac (19 cases) lung areas. The conventional screen-film system better showed small hilar calcifications (2 cases). From the protection viewpoint, at equivalent entrance doses, .15-.26. Gy/cm2 of dose-area product (DAP) values were reported with the digital system, using a tension of 150 kV in orthogonal projections, which are considerably lower than .25-.70 Gy/cm2 measured with the conventional technique. Moreover, Thoravision permitted to perform up to 100 exposures/hour, using a phantom, and 15-20 digital chest examinations/hour, versus the average 12-15 with the conventional screen-film system. The initial results are very encouraging from the clinical and cost-effectiveness viewpoints, thanks to higher Thoravision productivity and to exam optimization, even though wider and prolonged experience plus a careful study of diagnostic accuracy, sensitivity and specificity in each group of chest conditions is advisable, to assess the real innovative impact of this digital chest imaging system.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

