Uncertainty of calibrations at the accredited dosimetry calibration laboratories
G S Ibbott1, F H Attix, T W Slowey
1University of Kentucky, Lexington 40536, USA.
Abstract:
The American Association of Physicists in Medicine, through a subcommittee (formerly Task Group 3) of the Radiation Therapy Committee, has accredited five laboratories to perform calibrations of instruments used to calibrate therapeutic radiation beams. The role of the accredited dosimetry calibration laboratories (ADCLs) is to transfer a calibration factor from an instrument calibrated by the National Institute of Standards and Technology (NIST) to a customer's instrument. It is of importance to the subcommittee, to physicists using the services of the ADCLs, and to the ADCLs themselves, to know the uncertainty of instrument calibrations. The calibration uncertainty has been analyzed by asking the laboratories to provide information about their calibration procedures. Estimates of uncertainty by two procedures were requested: Type A are uncertainties derived as the standard deviations of repeated measurements, while type B are estimates of uncertainties obtained by other methods, again expressed as standard deviations. Data have been received describing the uncertainty of each parameter involved in calibrations, including those associated with measurements of charge, exposure time, and air density, among others. These figures were combined with the uncertainty of NIST calibrations, to arrive at an overall uncertainty which is expressed at the two-standard deviation level. For cable-connected instruments in gamma-ray and x-ray beams of HVL > 1 mm Al, the figure has an upper bound of approximately 1.2%.
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Propagation of Uncertainty from Systematic Error
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...