Simultaneous separate assessment of the cardiac and LVAD output
N I Chaus1, V V Kislukhin, S S Smirnov
1Department of Cardiosurgery, National Research Center of Surgery, Moscow, Russia.
Abstract:
The electroimpedance indicators' dilution (EIID) technique was used to study the possibility of a simultaneous separate assessment of the biological heart and LVAD performance in the position of LVB. The experimental part of the research was performed on 5 dogs; an artificial ventricle of the pulsing type (USA) with cusps was used as a pump. The clinical part of the work was conducted on 5 patients after open-heart surgery who had the clinical picture of postcardiotomy cardiogenic shock; a centrifugal pump "Biopump" (Medtronic, USA) was used. The authors have shown a principally important possibility of applying the EIID, technique for studying the performance curves which are the integral derivatives of the work of a specific hybrid system--"the biological heart-assist device". From the practical viewpoint the EIID technique permits in the read time mode to control continuously the part of the pumping function which is assumed by the patient's own heart. This information can serve as the basis for making the prognosis and determining the further tactics of treatment; the restoration of the heart performance or its replacement by transplantation.
More Related Videos
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
08:49Cardiac Loading using Passive Left Atrial Pressurization and Passive Afterload for Graft Assessment
Published on: August 2, 2024
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.