Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

An automated system for assessing metabolic and respiratory function during exercise

J H Wilmore, J A Davis, A C Norton

    Journal of Applied Physiology
    |April 1, 1976
    PubMed
    Summary

    A new automated system accurately assesses exercise metabolic and respiratory function. Validated against existing methods, it shows remarkable agreement across diverse exercise intensities for reliable physiological measurements.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Field applications of zein as a precise nanoscale delivery system for methoxyfenozide.

    Journal of insect science (Online)·2023
    Same author

    Belowground Herbivory to Sweetpotato by Sweetpotato Weevil (Coleoptera: Brentidae) Alters Population Dynamics and Probing Behavior of Aboveground Herbivores.

    Journal of economic entomology·2022
    Same author

    Author Correction: Motional narrowing, ballistic transport, and trapping of room-temperature exciton polaritons in an atomically-thin semiconductor.

    Nature communications·2022
    Same author

    A systematic review of gut microbiota composition in observational studies of major depressive disorder, bipolar disorder and schizophrenia.

    Molecular psychiatry·2022
    Same author

    Motional narrowing, ballistic transport, and trapping of room-temperature exciton polaritons in an atomically-thin semiconductor.

    Nature communications·2021
    Same author

    The role of diet quality and dietary patterns in predicting muscle mass and function in men over a 15-year period.

    Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA·2021

    Area of Science:

    • Exercise Physiology
    • Cardiorespiratory Function Assessment
    • Automated Measurement Systems

    Background:

    • Accurate assessment of metabolic and respiratory function during exercise is crucial for various physiological studies.
    • Existing systems for exercise assessment include computer-based and semi-automated methods, each with potential limitations.
    • There is a need for a fully automated system to streamline and enhance the accuracy of these measurements.

    Purpose of the Study:

    • To introduce and describe a novel, fully automated system for assessing metabolic and respiratory function during exercise.
    • To validate the accuracy and reliability of this new automated system by comparing it against two established assessment systems.
    • To determine the system's validity across a broad spectrum of metabolic exercise intensities (2 to >16 METs).

    Related Experiment Videos

    Main Methods:

    • The new automated system was evaluated concurrently with a computer-based system and a semi-automated system.
    • 112 participants (males and females, aged 12-65 years) performed graded arm or leg exercises on a cycle ergometer or treadmill.
    • Exercise intensity progressed from approximately 2 METs by 1 MET/min to volitional fatigue, with minute-by-minute respiratory and metabolic data collection.

    Main Results:

    • The new automated system demonstrated remarkable agreement with both established systems during exercise testing.
    • Comparisons revealed high concordance, even when considering potential sources of error inherent in each system.
    • While minor statistically significant differences were observed at lower work rates, the maximal difference in oxygen consumption (VO2) between any two systems was only 1.1 ml/kg-min.

    Conclusions:

    • The newly developed, fully automated system provides a valid and reliable method for assessing metabolic and respiratory function during exercise.
    • Its performance is comparable to established systems, offering a potentially more efficient and accurate alternative.
    • The system's accuracy across a wide range of exercise intensities supports its utility in diverse research and clinical applications.