Related Experiment Video
Updated: Jul 12, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 18, 2011
An examination of two emergency breathing aids for use during helicopter underwater escape
M J Tipton1, C M Franks, B A Sage
1Human & Applied Physiology Unit, Robens Institute, University of Surrey, Guildford, UK.
Background:
There is a paucity of published work in which the performance of Emergency Underwater Breathing Aids (EUBA) has been examined in the wide range of scenarios in which helicopter underwater escape may be necessary. In the present investigation two EUBA were examined: the Air Pocket (AP) rebreather and the Short Term Air Supply System (STASS) mini SCUBA set.
Method:
Young, healthy male subjects undertook simple simulated helicopter underwater escapes in water at 15 degrees C and/or 5 degrees C. During the immersions the subjects attempted to remain submerged for 60 s while traversing back and forth along a ladder secured at a depth of 1.25 m. At each temperature the subjects used AP and STASS twice. The subjects were dressed in the Royal Navy winter sea helicopter aircrew equipment assembly and an aircrew helmet.
Results:
Both AP and STASS significantly extended the underwater survival time of individuals when compared to their maximum breath-hold time (BHT). It is clear from the measurements made of gas concentrations in AP; the volume of air used from STASS; and subjective responses, that the 60-s submersions were achieved more easily with STASS than AP.
Conclusion:
It is concluded that in conditions similar to those of the present experiment STASS will give a longer underwater duration than AP, but this benefit must be offset against the possible risk of pulmonary barotrauma associated with the use of STASS, as well as increased training and maintenance costs. Irrespective of the EUBA which is provided, in-water training, preferably including exposure to cold water, will significantly improve the ability of an individual to use it.
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques