Related Experiment Videos
Influence of tissue preservation methods on arterial geometry and echogenicity
J E Wilhjelm1, K Vogt, S K Jespersen
1Department of Information Technology, Technical University of Denmark, Lyngby, Denmark. wilhjelm@it.dtu.dk
Abstract:
Thoracic porcine aortas from 5 pigs were investigated with 7.5-MHz ultrasound in vitro at low and high transmural pressure before and after the following tissue preservation methods were applied: 1. Storage in frozen condition (-12 degrees C) for 24 h followed by thawing; 2. fixation in formalin at zero transmural pressure for 24 h; and 3. fixation with formalin for 24 h while applying 74 mmHg of transmural pressure from within the lumen and a tensile force to longitudinally stretch the artery. Fixation in formalin at zero transmural pressure resulted in swelling of the arterial wall (25 +/- 40%, p < 0.02, at low transmural measurement pressure) and in decreased echogenicity (-23 +/- 38%, p < 0.01) of the arterial vessel wall. No changes in this respect were found after storage in a frozen condition nor after fixation in formalin at high transmural pressure which, therefore, are more appropriate procedures for fixation of arteries prior to in vitro ultrasound examination if geometry is important.