Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Continuous arch wire closing loop design, optimization, and verification. Part I

R E Siatkowski

    American Journal of Orthodontics and Dentofacial Orthopedics : Official Publication of the American Association of Orthodontists, Its Constituent Societies, and the American Board of Orthodontics
    |November 5, 1997
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Loss of anterior torque control due to variations in bracket slot and archwire dimensions.

    Journal of clinical orthodontics : JCO·2000
    Same author

    Lingual lever-arm technique for en masse translation in patients with generalized marginal bone loss.

    Journal of clinical orthodontics : JCO·2000
    Same author

    Wear and tear from sliding mechanics.

    Journal of clinical orthodontics : JCO·1998
    Same author

    Continuous arch wire closing loop design, optimization, and verification. Part II.

    American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics·1997
    Same author

    Optimal orthodontic space closure in adult patients.

    Dental clinics of North America·1996
    Same author

    The Otago dental lookover for improved clinical vision.

    Journal of clinical orthodontics : JCO·1995

    A new orthodontic loop design, the Opus loop, precisely controls force systems for accurate tooth movement. This innovation offers predictable translation, improving esthetics and stability in orthodontic treatments.

    Area of Science:

    • Orthodontics
    • Biomechanical Engineering
    • Dental Materials

    Background:

    • Continuous arch wires are fundamental in orthodontics.
    • Optimizing force systems is crucial for predictable tooth movement.
    • Existing loop designs may introduce unwanted moments, complicating treatment control.

    Purpose of the Study:

    • To systematically design and verify a novel closing loop for orthodontic arch wires.
    • To achieve a nonvarying moment-to-force (M/F) ratio for precise tooth translation.
    • To introduce the Opus loop, enhancing control over anteroposterior treatment goals.

    Main Methods:

    • Utilized Castigliano's theorem to derive M/F equations based on loop geometry.
    • Employed finite element simulations for design refinement.

    Related Experiment Videos

  • Conducted experimental validation of the new loop design and its performance.
  • Main Results:

    • Developed the Opus loop, inherently delivering a consistent M/F ratio (8.0–9.1 mm) without additional bends.
    • Demonstrated that precise loop bending is critical for achieving design potential.
    • Presented experimental data showing superior performance of the Opus loop compared to standard designs.

    Conclusions:

    • The Opus loop offers precise control over force systems, enabling accurate tooth movement and translation.
    • This design facilitates achieving esthetic and stability goals in orthodontic treatment.
    • The study highlights the importance of accurate manufacturing and provides application examples for varying anchorage needs.