Hemodynamic monitoring: a comparison of research and practice
Background:
Measurement of hemodynamic parameters is a common practice and is well researched, but little information is available on the translation of the research into actual practice.
Objectives:
To determine (1) the current practice of hemodynamic measurement in relation to positioning of patients and (2) the barriers to use of research related to hemodynamic monitoring.
Methods:
A stratified, random, national sample of 1000 members of the American Association of Critical-Care Nurses was surveyed by mail about hemodynamic monitoring procedures related to the positioning of patients and beds, technique used to determine the position of the bed, number of measurements of cardiac output, use of iced versus room-temperature injectate, use of printed or digital information, nurses' input into written procedures, and barriers to research utilization.
Results:
In actual practice, 24.1% of the respondents always keep the bed flat when measuring pulmonary artery pressures, 55.0% elevate the head of the bed 30 degrees or less, 80.7% always have patients supine for measurements, and 13.3% place patients in lateral or other positions. Unit policy dictated the flat position in 25.8% of the sample; nurse managers (41.4%), staff nurses (27.5%), and staff committees (31.2%) were involved in writing the procedure. Respondents viewed research related to hemodynamic monitoring procedures as relevant and valuable. The greatest barriers to utilization were lack of staff support for implementation, insufficient time to implement research findings, and feelings among nurses that they lacked authority to implement change.
Conclusions:
Research findings are generally being implemented at the bedside, although not completely or consistently. Minimizing the barriers to use of research is within the scope of nurses' practice.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure