Effect of hemolysis on serum retinol as assessed by direct fluorometry
Related Experiment Video
Updated: Oct 31, 2026

Real-time Analyses of Retinol Transport by the Membrane Receptor of Plasma Retinol Binding Protein
Published on: January 28, 2013
A C Marinovic1, W A May, A L Sowell
1Rollins School of Public Health, Emory University, Atlanta, GA, USA.
To assess the effect of hemolysis on serum retinol concentrations determined by direct fluorometry, we assayed 196 blood samples from children 6-72-mo of age with various grades of hemolysis for serum retinol by both fluorescence and HPLC. Mean serum retinol concentrations determined by HPLC did not differ significantly according to hemolysis grade; however, fluorometric values did. Additionally, serum retinol concentrations obtained from HPLC and those obtained from direct fluorometry were significantly different in samples with severe hemolysis. Multivariate-regression analysis showed that hemolysis grade was a significant predictor of the difference in mean serum retinol values determined by the two methods. Although severe hemolysis interfered with determinations of serum retinol by direct fluorometry, this method is still a viable choice for field studies of vitamin A status.
To assess the effect of hemolysis on serum retinol concentrations determined by direct fluorometry, we assayed 196 blood samples from children 6-72-mo of age with various grades of hemolysis for serum retinol by both fluorescence and HPLC. Mean serum retinol concentrations determined by HPLC did not differ significantly according to hemolysis grade; however, fluorometric values did. Additionally, serum retinol concentrations obtained from HPLC and those obtained from direct fluorometry were significantly different in samples with severe hemolysis. Multivariate-regression analysis showed that hemolysis grade was a significant predictor of the difference in mean serum retinol values determined by the two methods. Although severe hemolysis interfered with determinations of serum retinol by direct fluorometry, this method is still a viable choice for field studies of vitamin A status.
More Related Videos
07:29Cell-free Biochemical Fluorometric Enzymatic Assay for High-throughput Measurement of Lipid Peroxidation in High Density Lipoprotein
Published on: October 12, 2017
05:03Quantitative Analysis of Dietary Vitamin A Metabolites in Murine Ocular and Non-Ocular Tissues Using High-Performance Liquid Chromatography
Published on: December 27, 2024