Related Experiment Video
Updated: Jul 30, 2026

Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Determination of plasma concentrations of propofol associated with 50% reduction in postoperative nausea
T J Gan1, P S Glass, S T Howell
1Duke University Medical Center, Department of Anesthesiology, Durham, North Carolina 27710, USA. gan00001@mc.duke.edu
Background:
Subhypnotic doses of propofol possess direct antiemetic properties. The authors sought to determine the plasma concentration of propofol needed to effectively manage postoperative nausea and vomiting.
Methods:
Patients aged 18-70 yr who were classified as American Society of Anesthesiologists physical status 1 or 2 and had surgery during general anesthesia were approached for the study. Only patients who had nausea (verbal rating score > 5 on a 0- to 10-point scale), retching, or vomiting in the postanesthetic care unit participated. Propofol was administered to these patients to achieve target plasma concentrations of 100, 200, 400, and 800 ng/ml using a computer-assisted continuous infusion device. Target concentrations were increased every 15 min until patients described at least a 50% reduction in symptoms on the verbal rating score. An arterial blood sample was obtained at each step. The measured plasma propofol concentrations were used to analyze data. Blood pressure, heart and respiratory rates, arterial blood saturation, sedation score, and overall satisfaction with treatment were recorded.
Results:
Of the 89 patients who consented to the study, 15 patients met entry criteria and were enrolled. Five of these patients also had retching or vomiting when they entered the study. Fourteen patients responded successfully to treatment. One patient did not achieve the required response at plasma concentrations of 830 ng/ml. Hence the success rate for the treatment of postoperative nausea and vomiting was 93%. Among patients who responded, the median plasma concentration associated with an antiemetic response was 343 ng/ml. There was no difference in sedation scores from baseline and no episodes of desaturation. Hemodynamic parameters were stable during the study.
Conclusions:
Propofol is generally efficacious in treating postoperative nausea and vomiting at plasma concentrations that do not produce increased sedation. Simulations indicate that to achieve antiemetic plasma propofol concentrations of 343 ng/ml, a bolus dose of 10 mg followed by an infusion of approximately 10 microg x kg(-1) x min(-1) are necessary.
More Related Videos
Related Concept Videos
Local Anesthetics: Pharmacokinetics
Stages of General Anesthesia
Parenteral Anesthetics: Overview
Factors Affecting Drug Distribution: Organ Perfusion Rate
Perfusion rate-limited distribution relies on the...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations

