An outbreak of Candida parapsilosis prosthetic valve endocarditis

D J Diekema1, S A Messer, R J Hollis

  • 1Department of Internal Medicine, University of Iowa College of Medicine, Iowa City 52242, USA.

Insights

Candida parapsilosis is a rare cause of prosthetic valve endocarditis. Frequent glove tears in operating room staff may have led to transmission during valve replacement surgery, resulting in patient deaths.

Area of Science:

  • Infectious Diseases
  • Medical Microbiology
  • Surgical Infections

Background:

  • Candida parapsilosis is a significant nosocomial pathogen and a common contaminant on healthcare workers' hands.
  • Prosthetic valve endocarditis (PVE) caused by C. parapsilosis is uncommon.

Observation:

  • Four cases of C. parapsilosis PVE occurred within a four-month period at a community hospital.
  • All cases involved patients who underwent valve replacement surgery performed by the same surgical team.
  • The surgical team reported frequent tears in their hypoallergenic gloves during procedures.

Findings:

  • Molecular typing confirmed that the three available C. parapsilosis PVE isolates were genetically identical.
  • Hand cultures revealed C. parapsilosis in 26% of personnel, though the implicated surgeon and physician assistant later tested negative.
  • Environmental and other patient isolates showed diverse DNA types, distinct from the PVE case isolates.

Implications:

  • The study suggests a probable link between intraoperative glove tears and C. parapsilosis transmission during valve replacement surgery.
  • This highlights the critical importance of maintaining sterile techniques and intact gloves in preventing nosocomial infections.
  • Enhanced surveillance and preventative measures are crucial for managing C. parapsilosis in surgical settings.