Related Experiment Video
Updated: Jul 27, 2026

Measurement of Vibration Detection Threshold and Tactile Spatial Acuity in Human Subjects
Published on: September 1, 2016
The effects of skin temperature on the detection and discrimination of tactile stimulation
G A Gescheider1, J M Thorpe, J Goodarz
1Department of Psychology, Hamilton College, Clinton, NY 13323, USA.
Abstract:
Detection thresholds and intensity-difference thresholds were measured on four subjects ranging in age from 19 to 22 years. The stimuli were 250-Hz bursts of vibration applied through a 3.0 cm2 contactor to the thenar eminence of the right hand. Detection thresholds were substantially higher at 20 degrees C than at 30 degrees or 40 degrees C and were only slightly higher at 40 degrees C than 30 degrees C. When the intensity-difference threshold was expressed in relative terms, as the proportion by which two stimuli must differ in amplitude to be discriminated (delta phi/phi), discrimination capacities were unaffected by surface-skin temperature. The results are consistent with the hypothesis that surface-skin temperature alters the sensitivity of tactile receptors, and that, because of the 'near miss' to Weber's law, the relative difference threshold is unaffected substantially by skin temperature. It was concluded that, at least a partial explanation of the 'near miss' lies in the fact that, at low to moderate sensation levels, the P channel is exclusively activated whereas, at moderate to high sensation levels, because of recruitment of activity in Non-Pacinian channels, neural information for intensity discrimination is additionally provided by channels with superior discriminative capacities.
Related Concept Videos
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Sensory Functions of the Skin
There are two main categories of receptors on the skin: capsulated and non-capsulated. The non-capsulated ones are mainly the pain receptors. The capsulated ones can be further categorized based on the...
Tactile and Chemical Senses