Use of high-speed, high-resolution thermography to evaluate the tear film layer
1Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan.
Purpose:
To evaluate the tear film layer in patients with dry eye and in normal subjects by measuring the corneal temperature with infrared radiation thermography.
Methods:
One eye of each of 13 patients with dry eye and one eye of each of seven normal subjects were evaluated randomly. The corneal temperature was measured continuously with a recently improved infrared radiation thermography technique. We calculated the k value, which reflected the steepness of the corneal temperature change. The bigger the k value was, the more rapid was the decrease in corneal temperature, and this was directly related to increased evaporation.
Results:
With normal blinking, the mean k value for patients with dry eye (5.6 +/- 2.9 per second) was significantly less than that in the control subjects (9.3 +/- 5.0 per second; P < .05). Keeping the eyes open after closing the eyes significantly decreased the k values compared with normal blinking in both groups (P < .05).
Conclusions:
Our findings demonstrate the usefulness of this method of measuring corneal temperature to evaluate the tear film layer. High-speed, high-resolution thermography detected subtle changes in corneal temperature with enhanced sensitivity and spatial and temporal resolution. We found that the mean k value, and therefore the rate of decline in corneal temperature in patients with dry eye, was significantly less than that in normal subjects. The k value may therefore reflect tear film layer stability. The measurement of the changes in the corneal temperature can thus give us valuable information on the tear film layer.