Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
The agreement between colour Doppler systems in measuring internal carotid artery peak systolic velocities
S Wolstenhulme1, J A Evans, M J Weston
1Department of Ultrasound, St James's University, Leeds, UK.
Abstract:
The study was undertaken to determine if the internal carotid artery peak systolic velocities (ICA PSVs) measured by two colour Doppler imaging systems (Acuson 128 and Siemens Quantum) agree sufficiently for the two systems to be interchangeable in evaluating carotid artery disease. One operator obtained blinded measurements of ICA PSV in 63 prospective nonrandomized patients at risk of stroke. The operator examined 20 patients in the first cohort to assess the intraobserver variation, and 43 patients in the second cohort to assess the limits of agreement between the systems. In vitro comparisons of the systems were also undertaken, using both string and flow phantoms. Excluding one outlier, the intraobserver reproducibility coefficient for both machines was 0.48 m s-1. The limits of agreement (within which 95% of differences lie) between systems were -0.47 to 0.45 m s-1. This reduced to -0.39 to 0.33 m s-1 when the one outlier was excluded. This is within the intraobserver reproducibility range. In vitro data show little intersystem variation with phantom velocity. Intratransducer differences increase when the Doppler angle is increased using the string phantom; maximum differences: Acuson 0.30 m s-1 (42%) and Siemens 0.32 m s-1 (32%). These are within the in vivo reproducibility range. Intratransducer difference decreases when the Doppler angle is increased using the flow phantom, maximum differences: Acuson 0.05 m s-1 and Siemens 0.07 m s-1. The results show the systems agree sufficiently to be interchangeable in evaluating carotid artery disease; however, errors in maximum PSVs, caused by operator or system variation, may lead to errors in percent stenosis grading of the carotid arteries.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation