Hemodynamic tolerance of intravascular contrast agents for magnetic resonance imaging
F D Knollmann1, R Sorge, A Mühler
1Strahlenklinik und Poliklinik, Virchow Klinikum, Medizinische Fakultät, Humboldt-Universität zu Berlin, Germany.
Rationale And Objectives:
Intravascular contrast agents for magnetic resonance imaging (MRI) facilitate the quantification of tissue perfusion. The authors determined the hemodynamic tolerance of these agents.
Methods:
Doses of 0.05, 0.15, and 0.45 mmol/kg of the polymeric intravascular contrast agent gadolinium-DTPA-polylysine, and di-nitrobenzyl-gadolinium-DTPA, a non-polymeric intravascular contrast agent with high protein binding, and gadolinium-DTPA dimeglumine, a paramagnetic contrast agent with extracellular distribution, were injected into 18 normal male rats as a peripheral intravenous bolus. Systolic, diastolic, and mean blood pressure, left ventricular end-diastolic and developed pressure, positive rate of pressure change (+dP/dt), dP/dt, the rate-pressure product, and heart rate were recorded during a period of 20 minutes. Hemodynamic effects were established by analysis of variance for repeated measurements.
Results:
There was a transient increase of all blood pressure parameters and contractility for Gd-DTPA-polylysine at the dose of 0.45 mmol/kg only. Di-nitrobenzyl-Gd-DTPA increased blood pressure parameters at 0.45 mmol/kg only. At doses of 0.05 and 0.15 mmol/kg, no significant hemodynamic effects were observed.
Conclusions:
The authors conclude that Gd-DTPA-polylysine is hemodynamically safe at doses to 0.15 mmol/kg and acts like a plasma expander at higher doses after peripheral bolus injection in normal rats. Additional investigations are indicated to elucidate the mechanism of a nonsignificant and satiable transient hemodynamic depression after injection of 0.05 mmol/kg DNB-Gd-DTPA.