Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Non-invasive assessment of systemic elastic behaviour in hypertensive patients: analysis of possible determinants
A I Christen1, R A Sánchez, H P Baglivo
1Centro de Investigación de Ciencias Básicas, Instituto Universitario de Ciencias Biomédicas, Fundación Favaloro, Buenos Aires, Argentina.
Abstract:
Knowledge about the viscoelastic behaviour of the arterial wall has been proved to have physiological importance and clinical usage. Our purpose was to study the changes of the systemic arterial wall's elastic properties non-invasively, in patients with established essential and with borderline hypertension, and to evaluate its possible determinants. Three groups of normotensive, borderline and established essential hypertensive patients were evaluated. Arterial pulse wave velocity (PWV) was measured and arterial compliance (Cm) was derived in all patients. Pulse wave velocity was obtained from the pressure values of digitized carotid and radial arteries. Arterial compliance (Cm = dD/dP with P pressure and D diameter) was calculated using a formula derived from the Bramwell and Hill equation: Cm = (1,334 x D)/(2 rho x PWV2), where for D humeral diameter was used as measured by high resolution echograph, and rho is the blood density (rho = 1.06). Pulse wave velocity was significantly higher in established essential hypertensive patients with respect to normotensive patients (p < 0.05). Arterial compliance was significantly diminished in established and in borderline hypertensive patients with respect to normotensive patients (p < 0.05), which implies early alterations in hypertensive cardiovascular disease. Multiple regression analysis of the cofactors showed that age and diastolic pressure are independent determinants of Cm. Impairment of the arterial wall's intrinsic elastic properties was demonstrated in established essential hypertension, independent of age and diastolic pressure.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.