Hearing loss after continuous or single-shot spinal anesthesia

T Lamberg1, M T Pitkänen, T Marttila

  • 1Department of Anesthesia, Töölö Hospital, Helsinki, Finland.

Regional Anesthesia
|January 13, 1998
PubMed
Summary

Continuous spinal anesthesia using catheters did not prevent hearing loss after spinal anesthesia, despite potential dura plugging. Hearing impairment occurred in 37% of catheter patients versus 43% in single-shot, but lasted longer with catheters.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Immunogenicity of subcutaneous TNF inhibitors and its clinical significance in real-life setting in patients with spondyloarthritis.

Rheumatology international·2021
Same author

Current evidence is not in support of lipid rescue therapy in local anaesthetic systemic toxicity.

Acta anaesthesiologica Scandinavica·2016
Same author

The effects of intravenous lipid emulsion on hemodynamic recovery and myocardial cell mitochondrial function after bupivacaine toxicity in anesthetized pigs.

Human & experimental toxicology·2016
Same author

Intravenous lipid emulsion for levobupivacaine intoxication in acidotic and hypoxaemic pigs.

Anaesthesia and intensive care·2016
Same author

Incidence of severe local anaesthetic toxicity and adoption of lipid rescue in Finnish anaesthesia departments in 2011-2013.

Acta anaesthesiologica Scandinavica·2015
Same author

National critical incident reporting systems relevant to anaesthesia: a European survey.

British journal of anaesthesia·2013

Area of Science:

  • Anesthesiology
  • Neuroscience
  • Audiology

Background:

  • Post-spinal anesthesia hearing loss is linked to cerebrospinal fluid (CSF) leakage.
  • Spinal catheters might prevent CSF leakage via mechanical plugging and inflammation.
  • This study investigates if catheters mitigate hearing loss.

Purpose of the Study:

  • To evaluate the effectiveness of spinal catheters in preventing hearing loss post-spinal anesthesia.
  • To compare hearing outcomes between single-shot spinal anesthesia and continuous spinal anesthesia with catheters.

Main Methods:

  • Audiometric evaluation before and after anesthesia in 40 patients (21 single-shot, 19 continuous spinal).
  • Spinal catheters were in place for 24 hours.
  • Hearing impairment defined as a threshold change > 10 dB.

Related Experiment Videos

Main Results:

  • Hearing impairment occurred in 43% of the single-shot group and 37% of the continuous spinal group.
  • Hearing deterioration lasted significantly longer in the continuous spinal group (3 days vs. 1.4 days).

Conclusions:

  • Continuous spinal anesthesia with a 24-hour catheter did not prevent hearing loss.
  • Inflammatory swelling around the catheter did not preclude hearing impairment post-removal.