Related Experiment Video
Updated: Aug 19, 2026

Hyperpolarized Xenon for NMR and MRI Applications
Published on: September 6, 2012
Diffusion imaging with hyperpolarized 3He Gas
Abstract:
We used MRI of hyperpolarized 3He to demonstrate some novel aspects of gas diffusion. Two different techniques were used. First, a slice was burned into a one-dimensional image by inverting the spins in the slice and diffusion was studied by measuring the magnetization as it filled the depleted slice. A diffusion coefficient was determined by the fit of these data. Second, one-dimensional diffusion images were made using a Stejskal-Tanner PGSE method. This was done with and without a temperature gradient present, showing that the effect of temperature can be dynamically monitored by such diffusion images. Copyright 1997 Academic Press. Copyright 1997Academic Press