Related Experiment Video
Updated: Aug 30, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Imaging of dental implants in severely resorbed maxillae using detailed narrow-beam radiography. A methodological
1Department of Oral Diagnostic Radiology, Postgraduate Dental Education Center, Orebro, Sweden.
Objective:
To evaluate the accuracy of the detailed narrow-beam (DNB) technique with the Scanora multimodal X-ray unit for the assessment of dental implants in severely resorbed maxillae as an alternative to conventional intra-oral radiography.
Methods:
The DNB technique was used in 15 consecutive patients with maxillary overdentures supported by implants in the canine regions. Both conventional intra-oral radiographs and DNB radiographs were also obtained for a further 15 consecutive patients with maxillary fixed prostheses on implants in the canine region. The marginal bone height was scored in relation to the threads on the implants.
Results:
Intra-observer agreement was 95%. There was an 84% agreement between the two radiographic methods: the difference was at most one thread and was not significant (p = 0.43).
Conclusions: