Related Experiment Videos
Luminance contrast and colour contrast related errors in pseudoisochromatic plate identification
1Veterans Administration Hospital, Iowa City, Iowa, USA.
Purpose:
To determine whether differences in luminance contrast and colour contrast are factors in failing to identify American Optical pseudoisochromatic plates (AOPP).
Methods:
We studied two groups of subjects. In 20 normal test subjects with no errors on the AOPP we used cross-polarising filters to darken and then gradually increase perceived luminance of the AOPP until these normal subjects correctly identified the plate. In a second group, to evaluate the relationship between a luminance contrast sensitivity score using Arden plates and AOPP identification, we tested 37 non-colour-deficient subjects who missed zero to five of the AOPP of low colour and luminance contrast (plates 9-12, 15).
Results:
Using the cross-polarising filters, we found five plates that required more light to identify (plates 9-12, 15). In the second experiment, we found a significant relationship between the number missed of these five AOPP plates and a decrease in contrast sensitivity (r = 0.91, p < 0.001, Spearman correlation coefficient).
Conclusion:
Errors in AOPP colour plate detection may be due to loss of ability to perceive colour contrast and possibly luminance contrast.