[Breathing circuit exchange in intensive care. Once daily once weekly?]
Related Experiment Video
Updated: Oct 30, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
P Gastmeier1, C Wendt, H Rüden
1Institut für Hygiene, Freien Universität Berlin.
Unlabelled:
In an investigation of infection control methods for respirator systems in 89 randomly selected German intensive care units as a part of the NIDEP study (Nosocomial Infections in Germany--Surveillance and Prevention), it was found that respirator systems were exchanged daily in about 50% of the intensive care units. However, Craven et al. found that changing circuits (including tubing and exhalation valve and the attached humidifier) every 24 h rather than every 48 h was independently associated with the occurrence of nosocomial pneumonia. On the basis of these results and recent studies, the current situation in the literature was analyzed in order to make recommendations for exchanging ventilator circuits.
Methods:
Based on the extensive analysis of the literature by the Hospital Infection Control Practices Advisory Committee (HICPAC), we could limit our investigation to the years after 1994. A MEDLINE search was done, and abstracts from congresses of the past few years were considered. The main focus of the analysis was the development of pneumonia and not the contamination of the breathing circuit. The following methodological factors were analyzed for the most important published studies: design, applied definitions of pneumonia, sample size, comparability of study groups, inclusion and exclusion criteria. The results of the different studies were compared considering the potential bias factors.
Results And Discussion:
There were nine prospective controlled studies on this topic. In all studies, the authors tried to investigate whether a longer interval between ventilator circuit exchange (more than 48 h) is safe or whether it is possible to leave the circuits unchanged (without using breathing filters). The design and results of the available studies were analyzed. The three most important studies were compared very carefully (Table 1 and 2), and a recommendation for infection control measures for ventilator circuits was made as a modification of the HICPAC guidelines. In addition, the device-associated pneumonia rates of ventilated intensive care patients in the NIDEP study were analyzed separately according to a daily or a 48-h or longer interval of ventilator circuit exchange. For patients with daily exchange, we found a device-associated rate of 17.4 per 1000 ventilator days and for those with longer intervals a rate of 7.9 per 1000 ventilator days. Only considering those patients without heat and moisture filters, the figures were 14.8 versus 6.1. These differences were not significant because of the small number of patients investigated.
Conclusion:
The available studies show clear advantages of not routinely exchanging the ventilator circuit, including tubing, exhalation valve and the attached humidifier, more often then every 7 days for an individual patient. Based on these findings, the current practice in most German intensive care units should be reevaluated.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Continuous Renal Replacement Therapy
Cardiopulmonary Resuscitation II: ACLS Airway Management