Miniature dark adaptometer using tritium as a light source

F C Roger

    American Journal of Ophthalmology
    |August 1, 1976
    PubMed
    Summary

    A new miniature dark adaptometer allows for rapid measurement of rod function using disposable masks. This device enables 11 rod function tests within 1.5 hours, improving efficiency in clinical settings.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same journal

    Intraoperative Optical Coherence Tomography Navigated the Scleral Buckling.

    American journal of ophthalmology·2026
    Same journal

    Comment on: Conjunctival Biopsy in Ocular Mucous Membrane Pemphigoid.

    American journal of ophthalmology·2026
    Same journal

    Outcomes of nasal vertical rectus belly transposition and lateral rectus recession for large exotropia after medial rectus transection.

    American journal of ophthalmology·2026
    Same journal

    A Pseudolenticular Fibrin Membrane in Recurrent Hypopyon Uveitis.

    American journal of ophthalmology·2026
    Same journal

    Reply to: Conjunctival Biopsy in Ocular Mucous Membrane Pemphigoid.

    American journal of ophthalmology·2026
    Same journal

    Shaping the future of limbal stem cell therapy: advances in substrates, techniques, and science for cultivated autologous and allogeneic limbal-epithelial transplantation.

    American journal of ophthalmology·2026

    Area of Science:

    • Ophthalmology
    • Visual Neuroscience
    • Medical Instrumentation

    Background:

    • Accurate measurement of rod function is crucial for diagnosing and monitoring retinal diseases.
    • Traditional dark adaptometry can be time-consuming and require specialized equipment.

    Purpose of the Study:

    • To introduce a novel miniature dark adaptometer for efficient monophasic rod function assessment.
    • To evaluate the feasibility of obtaining multiple rod function measurements within a short timeframe.

    Main Methods:

    • A miniature dark adaptometer utilizing a tritium-phosphoric sulfide gas light source was employed.
    • Disposable masks were used to ensure hygiene and standardize measurements.
    • A calibration table accounting for the light source's known brightness decay rate was incorporated.

    Main Results:

    • The instrument facilitated the completion of 11 monophasic rod function measurements in just 1.5 hours.
    • The integrated calibration table accurately compensated for the light source's decay rate.

    Conclusions:

    • The miniature dark adaptometer offers a rapid and efficient method for assessing rod function.
    • This device has the potential to streamline clinical evaluations of retinal function.