Related Experiment Video
Updated: Jul 16, 2026

Comparison of Tobacco Host Cell Protein Removal Methods by Blanching Intact Plants or by Heat Treatment of Extracts
Published on: August 8, 2016
Effect of inline filtration on ViaSpan cold-storage solution
B J Mueller1, S A Guessford, T T Chen
1DuPont Merck Pharmaceutical Company, Wilmington, DE 19880, USA.
Abstract:
The effect of filtration on the particulate load in ViaSpan cold-storage solution was studied. Commercially available inline blood transfusion filters (SQ40S, Pall Biomedical) were inserted into the delivery-set port of polyvinyl chloride bags of ViaSpan (DuPont Merck Pharmaceutical). Particles in samples collected in particle-free vials before and after filtration were counted by a light-obscuration technique. The compatibility of key ViaSpan ingredients and of three commonly used additives (penicillin G potassium, dexamethasone sodium phosphate, and human insulin) with the inline filter was also investigated. Filtration removed 56% of particles 5-10 microm in diameter, 71% of particles of > 10-25 microm, and > 99% of particles measuring > 25 microm. Flow rates with the filters were more than adequate for clinical use. Concentrations of constituent hydroxyethyl starch, glutathione, adenosine, allopurinol, raffinose pentahydrate, and lactobionic acid were not significantly affected by filtration, nor were the concentrations of any of the drug additives. Inline filtration of ViaSpan effectively reduced fatty acid salt particulates in the solution and had no deleterious effect on flow rate, ingredient concentrations, or concentrations of commonly added drugs.
Related Concept Videos
Filtration
Physical Methods for Controlling Microbial Growth: Radiation and Filtration