Review of 10-year results of PCA hip arthroplasty
D E Hastings1, H Tobin, M Sellenkowitsch
1Department of Surgery, Wellesley Hospital, Toronto, Ont.
Objective:
To assess the long-term results of the PCA uncemented total hip replacement.
Design:
A prospective nonrandomized clinical trial. Follow-up ranged from 8 to 11 years (mean 10.3 years).
Setting:
A university hospital.
Patients:
One hundred consecutive PCA arthroplasties were performed on 89 patients. All operations were supervised by a single surgeon. The patients' status was reviewed between September and November 1996 by an independent observer. Seventy-three total hip replacements were available for review.
Intervention:
PCA uncemented acetabular and femoral replacement through a lateral surgical approach.
Main Outcome Measures:
The need for revision, which was classified as failure, and definite 3-zone acetabular radiolucency, which was considered radiologic evidence of loosening.
Results:
The time to failure of the acetabulum averaged 8 years. Femoral failure occurred in 3 patients an average of 4 years postoperatively. The overall failure rate for the acetabulum was 13% and for the femur 7%.
Conclusions:
The acetabular failure rate is unacceptably high. Patients who have had hip replacement with the PCA prosthesis should be followed over the long term.