Related Experiment Video
Updated: Aug 14, 2026

An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
Substitution of transpedicular screws by hook claws in a vertebrectomy model
J Y Margulies1, S A Caruso, D Chattar-Cora
1Department of Orthopedic Surgery, Montefiore Medical Center, Bronx, NY 10467, USA.
Abstract:
At times one pedicle screw cannot be used in a posterior construct because of morphometric reasons or when the pedicle is fractured intraoperatively. It is not clear from the literature whether and to what extent a construct's stability is compromised by substituting a hook claw for one pedicle screw. A synthetic vertebra model using a hook claw in lieu of a pedicle screw in a compressive and torsional mechanical study is evaluated. Isola screw-based constructs varying in the number of pedicle screws and hook claws were used. To recreate a realistic clinical scenario, transverse connectors and a Harms cage were used as well. In compression, substituting screws with claws did not substantially change the stiffness, whereas substituting one or two pedicle screws with one or two hook claws significantly reduced torsional stiffness. We conclude that using one or two hook claws is a viable alternative for pedicle screws when the latter cannot be used in a clinical situation, especially as an adjunct when the anterior column is reconstructed.