Related Experiment Video
Updated: Aug 12, 2026

Ultrasound Imaging of the Thoracic and Abdominal Aorta in Mice to Determine Aneurysm Dimensions
Published on: March 8, 2019
Measurement of the aorta and its branches with helical CT
G D Rubin1, D S Paik, P C Johnston
1Department of Radiology, Stanford University School of Medicine, CA 94305-5105, USA.
Abstract:
Contiguous orthonormal arterial cross sections, segment lengths, and curvature were semiautomatically quantified from helical computed tomographic (CT) angiographic data in phantoms and two patients. Measurements of mean diameter and curvature correlated with reference values (r2 = .99), and mean fractional errors were 0.07 and 0.06 for mean diameter and curvature measurements, respectively. Volumetric measurement showed a potential to increase the accuracy, precision, and diagnostic utility of CT angiography.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The Aorta
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...
Thoracic Aorta
Imaging Studies for Cardiovascular System V: CT
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aneurysm II: Clinical Manifestations and Diagnostic Studies